The store will not work correctly in the case when cookies are disabled.
CS Series Cost Effective Capacitance Decade Box
- Accurate 0.5% to 4%
- Wide range from 50 pF - 1000 µF (depending on model)
- Resolutions as good as 1 pF (depending on model)
- Broad choice of standard and optional models with many powerful features
- Compact, convenient, and rugged
DCCS DC Current Shunt Series
- Allows for high current calibration, up to 60 A
- Resistances ranges from 100 µΩ - 1 kΩ
- High accuracy 0.02%
- Suitable for direct current & audio frequencies
- Oil-filled design ensures great long term stability <0.01% over many years
HARS Series Resistance Decade Box
- Resistance from 1 mΩ to 111 MΩ
- Available in double-power version: HARS-X2
- Wide choice: single through 11 decade units
- High accuracy - 0.01% (100 ppm) or 0.1% depending on model
HRRS-5 kV & 10 kV Series - High Resistance Decade Box
- Choose from units with a max. resistance of 1 GΩ, 10 GΩ, 10 GΩ, 1TΩ or 11 TΩ
- Units use the most stable and accurate resistors and custom high voltage switches
- Maximum Voltages of 5000 V or 10,000 V. For 2000 V, consider the standard HRRS Series
- Used for calibration of Meggers and sourcing out precision high resistance.
LOM-510A Micro-Ohmmeter
- 1 μΩ resolution, 4½ digits
- Range: 1 μΩ - 200 Ω
- 0.02% basic accuracy
- Costs around 50% less then its peer instruments
OS-260 & OS-270 Resistance Decade Boxes / RTD Simulator
- The revolutionary ohmSOURCE microprocessor controlled resistor is like nothing you have ever seen before!
- US Patent 6487456
- Two cost-effective models available
- Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
- Engineered as an ideal RTD calibrator
- Unit can only be used as a MANUAL unit. Can not be connected to or controlled by a computer
RCS Series Resistance & Capacitance Box
- Combination of resistance and capacitance decades
- Accurate 0.1% to 4% (depending on model)
- Capacitance range 100 pF - 100 µF
- Resistance range 1 Ω - 10 MΩ
- Compact, convenient, and rugged
RS Series Resistance Substitution Box
- Accurate 0.1% to 1%
- Wide range from 0.01 Ω - 100 MΩ (Depending on Model)
- Broad choice of standard and optional models with many powerful features
- Compact, convenient, and rugged
RTD Series - Precision RTD Simulator
- Highest accuracy, highest stability, lowest TC of any RTD Simulator available
- Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
- Resolution: 1 mΩ (0.0025 ºC for PT 100)
- Stability 0.0002% for 24 hours; 0.001% for 12 months
SCA Series Capacitance Standard
- Values from 1 pF to 10,000 µF in any custom value available
- Stability as good as ±0.01 %/year
- Two-to-five terminal configuration, depending on model
- Excellent TC: as low as 10 ppm/°C
- 3 year warranty included
SRX-NI-4082 Standard Resistor Calibration Set
- Very stable - drift < 50 ppm/yr
- Excellent temperature coefficient - 2 ppm/°C
- Rugged
- Set consists of 4 resistance standards:
25 Ω, 125 Ω, 5 kΩ, 100 kΩ values as recommended by NI PXIe-408x calibration procedure
- 3/4" spacing for direct connection to the NI PXIe-4082
- Low inductance < 0.08 µH
- Accredited Calibration
- In addition to the standard values, any custom value is available. Please contact the IET sales department, for more information
VI-700 Precision Voltage & Current Source (Discontinued)
- Discontinued
- Voltage output range of 100 µV to 20 V or 200 V
- Current output range of 0.1 µA to 20 mA or 200 mA
- 3½ digit resolution, 0.75 LSD accuracy
- Manual thumbwheel operation or programmable digital input, IEEE-488 or RS232 interface
- May be used as a component in a closed loop control system
- Manufactured in the United States